John Hanso Sinaga - Quality and Inspection/Testing Manager

Specialties: High Voltage Equipments, Gas Insulated Switchgear (GIS), insulating gas gas handling, Lean Six Sigma, Continuous Improment, Quality and Inspection Aktivitas Joint our webinar “Optimal Approach for Pd Monitoring in Substation “, a single platform monitoring for various Main Transmission Equipments in…Get price

Summary Guidance for Operators of Equipment Containing SF and

Electrical switchgear which does not meet the exemptions above must be checked for leaks and if necessary repaired. The frequency of leak checking depends on the GWP of the F-gas (expressed in t CO 2 eq) as outlined in Table 1.Get price

Gas-insulated switchgear Inspection – China Certification

CCIC provide high quality Gas-insulated switchgear Inspection Service in China and abroad, to ensure safety and stable operation of entire power grid. Common fault analysis during Gas-insulated switchgear Inspection. In GIS switch, insulating gas gas is used as insulating carrier.Get price

sf 6 Gas Insulated Switchgear(GIS) Manufacturers and Suppliers

Sulfr hexafluoride gas insulated switchgear is utilized as insulation between the earthed metal enclosure and live parts of the equipment. This type of switchgear is accessible from 12 KV systems to 800 KV systems. This type of sf6 gas insulated switchgear plays a crucial role in establishing an electrical substation in very limited space.Get price

Sulfr hexafluoride Breaker Testing And Maintenance - Industrial Tests

Inspection for Sulfr hexafluoride or vacuum leaks should be performed by train technicians and engineers at ITI who perform services on par with NETA standards. Breaker contact resistance, insulation resistance of each pole to ground, over-potential tests, as well as others are all required to be completed at routine intervals for safe operational assurance.Get price

gaz sf6 INSULATED METAL-ENCLOSED SWITCHGEARS

• Protection switchgear for auxiliary services transformer and switch disconnector with fuses, up to 24 kV. • Auxiliary services transformer switchgear, attachable to or independent of the switchboard. SINGLE BUSBAR VERSION • Bus coupling switchgear with circuit-breaker (with or without) current measuring for 12 - 24 - 36 and 52 kV.Get price

Guidelines – Sulphur Hexafluoride Management

AS/NZS 2791:1996 High-voltage switchgear and controlgear—Use and handling of sulphur hexafluoride (Sulfr hexafluoride) in high-voltage switchgear andGet price

Medium Voltage Products | ABB

ABB is writing the future of sustainable energy distribution by extending its insulating gas-free medium-voltage (MV) switchgear portfolio. Having developed a new load break switch, ABB is partnering with multinational energy company Enel to bring technology to the market that is considerably better for the environment.Get price

Relevance of sf 6 in Switchgear and its Contribution to

These Sulfr hexafluoride alternative solutions include vacuum technology and solid insulated Switchgear designs. Their sf 6 free product range includes MMS, SVS, and Xiria to name a few. In addition to this, Eaton along with Coteq, USG Industrial Utilities, Driescher, and Nuventura are part of the Green Switching Initiative that promotes and champions the use of sf 6 alternatives whenever and wherever possible. ABB likewise offers HV and MV Switchgear with an Sulfr hexafluoride free breaking medium that has 99.99% lower GWP.Get price

Sulfr hexafluoride (GIS) gas insulated substation Manufacturer in China

The sf6 gas gas insulated substation (GIS) is assembled by several sf6 gas gas insulated switchgear configurations in an outdoor enclosure which could reach IP54 protection grade. With the advantage of sf6 gas gas insulating ability (the interrupting arcs capability is 100 times more than air), gas insulated substation could operate in stable condition forGet price

MV GIS ring main unit SafeRing - Gas insulated switchgear

Medium voltage (MV) Sulfr hexafluoride-insulated ring main unit for secondary distribution up to 40.5 kV, 630A SafeRing is a ring main unit (RMU) for the secondary distribution network. It is available in 18 different configurations suitable for most switching applications within the range from 6 to 40.5 kV.Get price

Sulfr hexafluoride circuit breaker maintenance | TD Guardian Articles

Jun 01, 2005 · The first generation of gaz sf6 circuit breakers was the lower voltage classes of 72kV and 145kV. As Sulfr hexafluoride breaker technology improved, circuit breaker manufacturers introduced a dual pressure design for 145kV through 800kV applications, as well as air-blast breakers utilizing sf6 gas as the line-to ground dielectric insulation.Get price

Assessment of sf6 gas Gas Insulation | EA Technology

Assessment of Sulphur Hexafluoride (sf6 gas) gas insulation. Testing SF 6 gas for impurities will therefore indicate potential issues with the switchgear.. Decomposition products arise during operation of SF 6 gas-insulated switchgear through arcing in moist or impure SF 6 gas.Get price

Ihsandi Dwinanto - Quality Test Engineer - Hitachi ABB Power

Process improvement in managing tracking movement and consumption of Sulfr hexafluoride (Sulfur Hexafluoride) gas. The existing paper based recording system is replaced by an user friendly, SQL database-driven web app with intuitive UI/UX , accessible only from inside the company network.Get price

Safety by design: solid insulated technologies challenge the

Fig. 1, the 4.16 kV switchgear interrupting rating would need to be 10 MVA/(1.73 X 4.16 kV)/0.0575 = 24.1 kA. Both are significant interrupting ratings for this class of switchgear. Historically, gaz sf6 has been applied by utilities in high-voltage systems above 38 kV. Over the course of the pastGet price

sf 6 Gas Insulated Switchgear Guide Specification

Furnish gaz sf6 Insulated Switchgear as detailed in Sections 3.0 through 13.0 of these specifications. Any drawings or data sheets attached to the inquiry shall be considered part of this specification. The equipment shall be complete and operable. Provide production tests and inspections as detailed in Section 11.0 of this specification.Get price

Siemens develops Sulfr hexafluoride-free gas-insulated medium-voltage switchgear

This type-tested system is used to switch high currents at the primary distribution level. The single-pole encapsulated 8DAB 12 is a Sulfr hexafluoride-free medium-voltage switchgear in the Siemens blue GIS portfolio. Switches and switchgear that use Sulfr hexafluoride as the insulating, switching, and extinguishing gas remain an important part of the Siemens portfolio.Get price

Ring Main Unit and Switchgear Components Manufacturer in China

Ideal Power Transmission and Distribution System Jihui Electric Group Co., Ltd. is a science and technology professional company specializing in power transmission and distribution electrical equipment and new energy industry below 35KV. The company has complete technical inspection equipment, test report, and qualification certificate. Since its establishment more than ten years ago, theGet price

Alternatives for Sulfr hexafluoride | 2020 | Siemens Energy Global

Alternatives for Sulfr hexafluoride urgently sought In most of the worldsubstations sulfur hexafluoride (SF 6 ) is the insulating gas of choice. Still, due its potential climate impact, industry is looking for environmentally friendly solutions – and they have options.Get price

Digital radiography for inspection of Sulfr hexafluoride | TD Guardian

Apr 01, 2006 · However, unlike oil breakers, sf6 gas, air, and vacuum breakers lend themselves well to DR inspection. Based on the quantity and criticality of sf6 gas breakers, Siemens determined that this would be the most applicable medium and circuit breaker to inspect utilizing DR.Get price

Myth About sf 6 Gas In Electrical Equipment

Aug 24, 2017 · 5. How wide is the use of Sulfr hexafluoride in transmission and distribution switchgear applications ? sf6 gas insulated switchgear is currently used world-wide. It is estimated that an average of about 80 % of HV equipment manufactured now has an Sulfr hexafluoride content. 6. Why is Sulfr hexafluoride used in electric power equipment?Get price

Health and environmental dangers of sf 6-filled switchgear

Aug 08, 2017 · gaz sf6 gas, used as a dielectric medium in circuit breakers and switchgear, has a global warming potential 24 000 times greater than CO2 and some of its by-products were used as chemical weapons in World War I. In life, in business, in the ordinary course of doing things, there is a certain level of risk […]Get price

Sulfr hexafluoride Equipment Maintenance, Repair, and Replacement and

Sulfr hexafluoride replacemen t of Sulfr hexafluoride gas equipmen . Mike McNulty Manager Environmental Developed the EMS and Sulfr hexafluoride gas Jessica Uher Manager Warehouse Logistics Substation Maintenance Operation Maintains, repairs, and replaces sf 6 it Equipment Engineering Developed the EMS and sf 6 gas Evaluates insulating gas gas equipment/assets management procedures. OverseesGet price

Suicide Bomb Hits Palm Sunday Mass in Indonesia, 14 Wounded

Mar 28, 2021 · Police officers inspect the area near a church where an explosion went off in Makassar, South Sulawesi, Indonesia, Sunday, March 28, 2021. A suicide bomber blew himself up outside a packed RomanGet price

Minor inspection list for gas insulated switchgear GIS

Mar 22, 2019 · This inspection can be performed every 5–10 years on GIS components but the inspection can also be dependent on a number of operations of switching devices and manufacturer’s recommendations . The purpose is to check the proper operation of all switching devices. For this, the corresponding equipment needs to be de energized. GIS manufacturers provide …Get price

Sulfr hexafluoride properties, and use in MV and HV switchgear

3 Overview on gaz sf6 switchgear 3.1 MV and HV switchgear p.11 3.2 Sulfr hexafluoride consumption and switchgear quantities p.12 3.3 EDF experience: 20 years of Sulfr hexafluoride in MV p.13 3.4 Future trends p.13 4 Use and handling of Sulfr hexafluoride in switchgear 4.1 Filling with new Sulfr hexafluoride p.14 4.2 Leakage from sf6 gas - filled equipment p.15 4.3 Maintenance of insulating gas - filled equipment p.15Get price

gaz sf6 Free HV GIS and Breakers - US EPA

hermetically sealed gas insulated switchgear (GIS) CARB • Report annually by June 1 • Resubmit report within 45 days (plus an additional 30 days if requested) of substantive errors being discovered [adopted 40 CFR Part 98.3(h) by reference] • Report calculated annual sf6 gas emissions (lbs) and calculated gaz sf6 emission rate for onlyGet price

HV/MV Circuit Breaker, Maintenance, Safe Operation amp

Nov 01, 2015 · HV/MV Circuit Breaker, Maintenance, Safe Operation Theory Course Published on November 1, 2015 November 1, 2015 • 32 Likes • 6 CommentsGet price

The Problem with Humidity in insulating gas Gas-Insulated Systems

Apr 17, 2018 · Sulfur hexafluoride (gaz sf6) has excellent dielectric capabilities and is widely used as an insulator in power grid switchgear. Humidity in insulating gas gas, however, can decrease its insulation strength, promote corrosion, and cause failures.Get price